Excellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair Joint

Type: Wrapped Cable Joint
Material: PE
Application: Cable Joints
Character: Insulation
Species: Terminal
Production Process: Wrapped
Samples:
US$ 50/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Jiangsu, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
to see all verified strength labels (27)

Basic Info.

Model NO.
VRBJ
Shape
Round
Interface Type
Tbd
Certification
ISO9001
Brand
9V
Transport Package
Carton
Specification
Various
Trademark
9V
Origin
China

Product Description

10-20-35kV
Excellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair Joint
Operating parameters
Item No. Rated Voltage 5 minutes power frequency withstand voltage Universal cable cross section Working Temperature
VRBJ-10KV 10KV 39KV 25~630mm² Long-term 90ºC. Overload 130ºC
VRBJ-20KV 20KV 54KV 35~630mm² Long-term 90ºC. Overload 130ºC
VRBJ-35KV 35KV 117KV 50~630mm² Long-term 90ºC. Overload 130ºC
Tech Data
Test Item Technical Requirements (10KV) Technical Requirements (35KV) Test Result
AC withstand voltage test 39KV, 5min, No breakdown 117KV, 5min, No breakdown Pass
Partial discharge test at room temperature 15KV,<10pC 45KV,<10pC Pass
Impulse voltage test 95ºC~100ºC, ±95KV, 10 times each without breakdown 95ºC~100ºC, ±200KV, 10 times each without breakdown Pass
Constant pressure load cycle test in  air 22KV, 95ºC~100ºC, heating for 5h per cycle, cooling for 3h. No breakdown for a total of 30 cycles 65KV, 95ºC~100ºC, heating for 5h per cycle, cooling for 3h. No breakdown for a total of 30 cycles Pass
Constant pressure load cyclic test in water 22kV, 95ºC~100ºC, heating for 5h per cycle, cooling for 3h. No breakdown for a total of 30 cycles 65KV, 95ºC~100ºC, heating for 5h per cycle, cooling for 3h. No breakdown for a total of 30 cycles Pass

Excellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair JointExcellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair JointExcellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair Joint
Excellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair JointExcellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair JointExcellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair JointExcellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair JointExcellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair JointExcellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair JointExcellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair JointExcellent Underground Cable Connector Vrbj Wrapped Intermediate Joint Cable Repair Joint


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now