3kv Heat Shrinkable Cable Termination Joint Kits

Product Details
Customization: Available
Certification: Ticw
Color: Black / Red / Grey
Still deciding? Get samples of US$ 30/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
to see all verified strength labels (27)
  • 3kv Heat Shrinkable Cable Termination Joint Kits
  • 3kv Heat Shrinkable Cable Termination Joint Kits
  • 3kv Heat Shrinkable Cable Termination Joint Kits
  • 3kv Heat Shrinkable Cable Termination Joint Kits
  • 3kv Heat Shrinkable Cable Termination Joint Kits
  • 3kv Heat Shrinkable Cable Termination Joint Kits
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Recommended Product
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
VSJ / VSZ
IP Rating
IP68
Usage
Cable Joint
Material
PE
Type
1~5-Cores
Isolation Layer
2mm
Standard
GB811-P5
Voltage Class
LV & Mv (35kv and Below)
Temperature
-50 ~105
Transport Package
Carton
Specification
Varous
Trademark
9V
Origin
Jiangsu, China
HS Code
8547909000

Packaging & Delivery

Package Size
50.00cm * 20.00cm * 20.00cm
Package Gross Weight
6.000kg

Product Description

 
Product Description

Heat-shrinkable cable terminals
It commonly known as heat-shrinkable cable heads, are widely used on the terminals of cross-linked cables or oil-immersed cables with voltage levels of 35KV and below. Compared with the traditional cable accessories, the intermediate connection of the cable has the characteristics of small size, light weight, safety and reliability, and convenient installation.

Detailed Photos
3kv Heat Shrinkable Cable Termination Joint Kits
3kv Heat Shrinkable Cable Termination Joint Kits
3kv Heat Shrinkable Cable Termination Joint Kits
 
3kv Heat Shrinkable Cable Termination Joint Kits
3kv Heat Shrinkable Cable Termination Joint Kits
3kv Heat Shrinkable Cable Termination Joint Kits
Product Parameters

0.6/1KV-Heat Shrinkable Cable Accessories

Name Item No. Suit cables' sectional area (sqmm) Name Item No. Suit cables' sectional area (sqmm)
0.6/1kV Single Core Heat Shrinkable Termination Kits VSZ-1/1.0 10~16 0.6/1kV Single Core Heat Shrinkable Joint VSJ-1/1.0 10~16
VSZ-1/1.1 25~50 VSJ-1/1.1 25~50
VSZ-1/1.2 70~120 VSJ-1/1.2 70~120
VSZ-1/1.3 150~240 VSJ-1/1.3 150~240
VSZ-1/1.4 300~400 VSJ-1/1.4 300~400
0.6/1kV 2-cores Heat Shrinkable Termination Kits VSZ-1/2.0 10~16 0.6/1kV 2-cores Heat Shrinkable Joint VSJ-1/2.0 10~16
VSZ-1/2.1 25~50 VSJ-1/2.1 25~50
VSZ-1/2.2 70~120 VSJ-1/2.2 70~120
VSZ-1/2.3 150~240 VSJ-1/2.3 150~240
VSZ-1/2.4 300~400 VSJ-1/2.4 300~400
0.6/1kV 3-cores Heat Shrinkable Termination Kits VSZ-1/3.0 10~16 0.6/1kV 3-cores Heat Shrinkable Joint VSJ-1/3.0 10~16
VSZ-1/3.1 25~50 VSJ-1/3.1 25~50
VSZ-1/3.2 70~120 VSJ-1/3.2 70~120
VSZ-1/3.3 150~240 VSJ-1/3.3 150~240
VSZ-1/3.4 300~400 VSJ-1/3.4 300~400
0.6/1kV 4-cores Heat Shrinkable Termination Kits VSZ-1/4.0 10~16 0.6/1kV 4-cores Heat Shrinkable Joint VSJ-1/4.0 10~16
VSZ-1/4.1 25~50 VSJ-1/4.1 25~50
VSZ-1/4.2 70~120 VSJ-1/4.2 70~120
VSZ-1/4.3 150~240 VSJ-1/4.3 150~240
VSZ-1/4.4 300~400 VSJ-1/4.4 300~400
0.6/1kV 5-cores Heat Shrinkable Termination Kits VSZ-1/5.0 10~16 0.6/1kV 5-cores Heat Shrinkable Joint VSJ-1/5.0 10~16
VSZ-1/5.1 25~50 VSJ-1/5.1 25~50
VSZ-1/5.2 70~120 VSJ-1/5.2 70~120
VSZ-1/5.3 150~240 VSJ-1/5.3 150~240
VSZ-1/5.4 300~400 VSJ-1/5.4 300~400
Test Project Test Method Test Result/Conclusion
1min Power Frequency Voltage (wet state) 4kV, No breakdown no flashover No flashover and breakdown of the combined sample under 4kV, 1min wet state
Heating Cycles Voltage Test Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles Complete three load cycle tests as required by the standard
4H Power Frequency Voltage Test 2.4kV, No breakdown no flashover No flashover and breakdown of combined specimens
8.7/15KV-Heat Shrinkable Cable Accessories
Name Item No. Suit cables' sectional area (sqmm) Name Item No. Suit cables' sectional area (sqmm)
8.7/15kV Single Core Heat Shrinkable Indoor Termination Kits VRSN-10/1.1 25~50 8.7/15kV 3-cores Heat Shrinkable Indoor Termination Kits VRSN-10/3.1 25~50
VRSN-10/1.2 70~120 VRSN-10/3.2 70~120
VRSN-10/1.3 150~240 VRSN-10/3.3 150~240
VRSN-10/1.4 300~400 VRSN-10/3.4 300~400
VRSN-10/1.5 500~630 VRSN-10/3.5 500~630
8.7/15kV Single Core Heat Shrinkable Outdoor Termination Kits VRSW-10/1.1 25~50 8.7/15kV 3-cores Heat Shrinkable Outdoor Termination Kits VRSW-10/3.1 25~50
VRSW-10/1.2 70~120 VRSW-10/3.2 70~120
VRSW-10/1.3 150~240 VRSW-10/3.3 150~240
VRSW-10/1.4 300~400 VRSW-10/3.4 300~400
VRSW-10/1.5 500~630 VRSW-10/3.5 500~630
8.7/15kV Single Core Heat Shrinkable Joint VRSJ-10/1.1 25~50 8.7/15kV 3-cores Heat Shrinkable Joint VRSJ-10/3.1 25~50
VRSJ-10/1.2 70~120 VRSJ-10/3.2 70~120
VRSJ-10/1.3 150~240 VRSJ-10/3.3 150~240
VRSJ-10/1.4 300~400 VRSJ-10/3.4 300~400
VRSJ-10/1.5 500~630 VRSJ-10/3.5 500~630
Test Project Standard Requirements Test Result/Conclusion
1min Power Frequency Voltage (wet state) 45kV, No breakdown no flashover No flashover and breakdown of the combined sample under 45kV, 1min wet state
Partial discharge test 13kV devolution power not more than 20PC 13kV≤20PC A, B, C three-phase discharge capacity is 2PC under 13kV
Heating Cycles Voltage Test Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles Complete three load cycle tests as required by the standard
Impulse Voltage Test 105kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen 105kV positive and negative polarity 10 times each, no flashover and breakdown
Negative Polarity DC Voltage Test 52kV, No breakdown no flashover 52kV, 15min, No flashover and breakdown of combined specimens
4H Power Frequency Voltage Test 35kV, No breakdown no flashover 35kV, 4h, No flashover and breakdown of combined specimens

12/20KV 18/20KV-Heat Shrinkable Cable Accessories
 
Name Spec. (Single Core) Spec. (3-cores) Suit cables' sectional area (sqmm)
12/20kV 18/20kV
12/20kV Single Core / 3-cores Heat Shrinkable Indoor Termination Kits VRSN-20/1.1 VRSN-20/3.1 35~70 ------
VRSN-20/1.2 VRSN-20/3.2 95~185 35~70
VRSN-20/1.3 VRSN-20/3.3 240~400 95~185
VRSN-20/1.4 VRSN-20/3.4 500~630 240~400
12/20kV Single Core / 3-cores Heat Shrinkable Outdoor Termination Kits VRSW-20/1.1 VRSW-20/3.1 35~70 ------
VRSW-20/1.2 VRSW-20/3.2 95~185 35~70
VRSW-20/1.3 VRSW-20/3.3 240~400 95~185
VRSW-20/1.4 VRSW-20/3.4 500~630 240~400
12/20kV Single Core / 3-cores  Heat Shrinkable Joint VRSJ-20/1.1 VRSJ-20/3.1 35~70 ------
VRSJ-20/1.2 VRSJ-20/3.2 95~185 35~70
VRSJ-20/1.3 VRSJ-20/3.3 240~400 95~185
VRSJ-20/1.4 VRSJ-20/3.4 500~630 240~400
Test Project Standard Requirements Test Result/Conclusion
1min Power Frequency Voltage (wet state) 54kV, No breakdown no flashover No flashover and breakdown of the combined sample under 54kV, 1min wet state
Partial discharge test 13kV devolution power not more than 20PC 20kV≤20PC A, B, C three-phase discharge capacity is 1pc under 20kV
Heating Cycles Voltage Test Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles Complete three load cycle tests as required by the standard
Impulse Voltage Test 125kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen 125kV positive and negative polarity 10 times each, no flashover and breakdown
Negative Polarity DC Voltage Test 156kV, No breakdown no flashover 156kV, 15min, No flashover and breakdown of combined specimens
4H Power Frequency Voltage Test 104kV, No breakdown no flashover 104kV, 4h, No flashover and breakdown of combined specimens
 
26/35KV-Heat Shrinkable Cable Accessories
Name Item No. Suit cables' sectional area (sqmm) Name Item No. Suit cables' sectional area (sqmm)
26/35kV Single Core Heat Shrinkable Indoor Termination Kits VRLN-35/1.1 50~95 26/35kV 3-cores Heat Shrinkable Indoor Termination Kits VRLN-35/3.1 50~95
VRLN-35/1.2 120~185 VRLN-35/3.2 120~185
VRLN-35/1.3 240~400 VRLN-35/3.3 240~400
VRLN-35/1.4 500~630 VRLN-35/3.4 500~630
26/35kV Single Core Heat Shrinkable Outdoor Termination Kits VRLW-35/1.1 50~95 26/35kV 3-cores Heat Shrinkable Outdoor Termination Kits VRLW-35/3.1 50~95
VRLW-35/1.2 120~185 VRLW-35/3.2 120~185
VRLW-35/1.3 240~400 VRLW-35/3.3 240~400
VRLW-35/1.4 500~630 VRLW-35/3.4 500~630
26/35kV Single Core Heat Shrinkable Joint VRLJ-35/1.1 50~95 26/35kV 3-cores Heat Shrinkable Joint VRLJ-35/3.1 50~95
VRLJ-35/1.2 120~185 VRLJ-35/3.2 120~185
VRLJ-35/1.3 240~400 VRLJ-35/3.3 240~400
VRLJ-35/1.4 500~630 VRLJ-35/3.4 500~630
Test Project Standard Requirements Test Result/Conclusion
1min Power Frequency Voltage (wet state) 105kV, No breakdown no flashover No flashover and breakdown of the combined sample under 105kV, 1min wet state
Partial discharge test 13kV devolution power not more than 10PC 39kV≤10PC A, B, C three-phase discharge capacity is 4pc under 39kV
Heating Cycles Voltage Test Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles Complete three load cycle tests as required by the standard
Impulse Voltage Test 250kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen 250kV positive and negative polarity 10 times each, no flashover and breakdown
Negative Polarity DC Voltage Test 156kV, No breakdown no flashover 156kV, 15min, No flashover and breakdown of combined specimens
4H Power Frequency Voltage Test 104kV, No breakdown no flashover 104kV, 4h, No flashover and breakdown of combined specimens
 
Recommended Product

View more products,you can click photos...

3kv Heat Shrinkable Cable Termination Joint Kits
3kv Heat Shrinkable Cable Termination Joint Kits
3kv Heat Shrinkable Cable Termination Joint Kits

     66~500kV High Voltage Cable Accessories              1~35kV Cold Shrink Cable Accessories                                        Grounding Box

3kv Heat Shrinkable Cable Termination Joint Kits
3kv Heat Shrinkable Cable Termination Joint Kits
3kv Heat Shrinkable Cable Termination Joint Kits

      Customized Silicone Rubber Protector                                Heat Shrinkable Tubing                                                  Explosion Proof Box

Company Profile
3kv Heat Shrinkable Cable Termination Joint Kits3kv Heat Shrinkable Cable Termination Joint Kits3kv Heat Shrinkable Cable Termination Joint Kits3kv Heat Shrinkable Cable Termination Joint Kits
Packaging & Shipping

3kv Heat Shrinkable Cable Termination Joint Kits
FAQ
3kv Heat Shrinkable Cable Termination Joint Kits
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier