No. | Item | Inspection Area | Test result | Content | ||||||||
1 | Structure inspection | The whole machine | Pass | 1) The nameplate mark is in accordance with the standard provisions; 2) The structure size is in accordance with the drawings and standards. |
||||||||
2 | Temperature test | Shell, gasket, joint, single core cable joint potting part | Pass | The maximum surface temperatures of the sample shell, gasket, joints, and single-core cable joint potting parts were 63.5°C, 62.4°C, 106.6°C, and 106.1°C, respectively. Note 1: The cross-sectional area of the test cable is 300mm2. |
||||||||
3 | Heat-resistant hardy test | Gasket, cement and single core cable joint potting part | Pass | The sample was placed in an environment with a relative humidity of 90% and a temperature of 90°C for 14 days, and was placed in an environment of 127.0°C for 14 days, then placed at room temperature for 24 hours, and then placed in an environment with a temperature of 30°C for 24 hours, and sealed after the test. There was no obvious change in the sealing part of the mat, glue and single-core cable joint. | ||||||||
4 | Protest against the impact test | Shell | Pass | The shell withstands the impact energy generated by the test object with a mass of 1.0kg falling vertically from a height of 0.7m, and the result is no damaged. | ||||||||
5 | Insulation dielectric strength test | relatively | Pass | 1. Test voltage: 21000V; 2. Test time: 60s; 3. Test results: no breakdown, arcing, flashover phenomenon. |
||||||||
6 | Enclosure protection class (IP) test | The whole machine | Pass | Level 4 waterproof test: use a pendulum pipe water spray test device with a total flow of 4.3L/min and a test time of 10min. After the test, check that there is no water in the sample. The interior is completely filled with no cavities, meeting the requirements of class 5 dustproof. | ||||||||
7 | Introduce the device clamp test | introduction device | Pass | A tensile force of 720M was applied to the cable with a diameter of 36.0mm for 6 hours, and there was no displacement. | ||||||||
8 | Surface resistance measurement | The sample piece | Pass | Surface resistance value is 6.58 x 108Ω. |