Product Description
Cold-shrinkable cable termination kit & straight joint kit
This product adopts high quality liquid silicone rubber,The excellent performance, stress control material, and strong resistance to electric traces will make the cold shrinkable cable accessories become the first choice in the industry.
Advantages include installation without fire, construction time and space saving, a model can be applied to a variety of cable diameter.
Product Parameters
0.6/1KV-Cold Shrinkable Cable Accessories
Name |
Item No. |
Suit cables' sectional area (sqmm) |
Name |
Item No. |
Suit cables' sectional area (sqmm) |
0.6/1kV 3-cores Cold Shrinkable Termination Kits |
VLZ-1/3.0 |
10~16 |
0.6/1kV 3-cores Cold Shrinkable Joint |
VLJ-1/3.0 |
10~16 |
VLZ-1/3.1 |
25~50 |
VLJ-1/3.1 |
25~50 |
VLZ-1/3.2 |
70~120 |
VLJ-1/3.2 |
70~120 |
VLZ-1/3.3 |
150~240 |
VLJ-1/3.3 |
150~240 |
VLZ-1/3.4 |
300~400 |
VLJ-1/3.4 |
300~400 |
0.6/1kV 4-cores Cold Shrinkable Termination Kits |
VLZ-1/4.0 |
10~16 |
0.6/1kV 4-cores Cold Shrinkable Joint |
VLJ-1/4.0 |
10~16 |
VLZ-1/4.1 |
25~50 |
VLJ-1/4.1 |
25~50 |
VLZ-1/4.2 |
70~120 |
VLJ-1/4.2 |
70~120 |
VLZ-1/4.3 |
150~240 |
VLJ-1/4.3 |
150~240 |
VLZ-1/4.4 |
300~400 |
VLJ-1/4.4 |
300~400 |
0.6/1kV 5-cores Cold Shrinkable Termination Kits |
VLZ-1/5.0 |
10~16 |
0.6/1kV 5-cores Cold Shrinkable Joint |
VLJ-1/5.0 |
10~16 |
VLZ-1/5.1 |
25~50 |
VLJ-1/5.1 |
25~50 |
VLZ-1/5.2 |
70~120 |
VLJ-1/5.2 |
70~120 |
VLZ-1/5.3 |
150~240 |
VLJ-1/5.3 |
150~240 |
VLZ-1/5.4 |
300~400 |
VLJ-1/5.4 |
300~400 |
Test Project |
Standard Requirements |
Test Result/Conclusion |
Power Frequency Voltage Test |
4kV/1min,No breakdown no flashover |
Pass,meet the requirements |
Power Frequency Voltage Test |
2.4kV/4 hours,No breakdown no flashover |
Pass,meet the requirements |
8.7/15KV-Cold Shrinkable Cable Accessories
Name |
Item No. |
Suit cables' sectional area (sqmm) |
Name |
Item No. |
Suit cables' sectional area (sqmm) |
8.7/15kV 3-cores Cold Shrinkable Indoor Termination Kits |
VLN-10/3.1 |
25~50 |
8.7/15kV Single Core Cold Shrinkable Indoor Termination Kits |
VLN-10/1.1 |
25~50 |
VLN-10/3.2 |
70~120 |
VLN-10/1.2 |
70~120 |
VLN-10/3.3 |
150~240 |
VLN-10/1.3 |
150~240 |
VLN-10/3.4 |
300~400 |
VLN-10/1.4 |
300~400 |
VLN-10/3.5 |
500~630 |
VLN-10/1.5 |
500~630 |
8.7/15kV 3-cores Cold Shrinkable Outdoor Termination Kits |
VLW-10/3.1 |
25~50 |
8.7/15kV Single Core Cold Shrinkable Outdoor Termination Kits |
VLW-10/1.1 |
25~50 |
VLW-10/3.2 |
70~120 |
VLW-10/1.2 |
70~120 |
VLW-10/3.3 |
150~240 |
VLW-10/1.3 |
150~240 |
VLW-10/3.4 |
300~400 |
VLW-10/1.4 |
300~400 |
VLW-10/3.5 |
500~630 |
VLW-10/1.5 |
500~630 |
8.7/15kV 3-cores Cold Shrinkable Joint |
VLJ-10/3.1 |
25~50 |
8.7/15kV Single Core Cold Shrinkable Joint |
VLJ-10/1.1 |
25~50 |
VLJ-10/3.2 |
70~120 |
VLJ-10/1.2 |
70~120 |
VLJ-10/3.3 |
150~240 |
VLJ-10/1.3 |
150~240 |
VLJ-10/3.4 |
300~400 |
VLJ-10/1.4 |
300~400 |
VLJ-10/3.5 |
500~630 |
VLJ-10/1.5 |
500~630 |
Test Project |
Standard Requirements |
Test Result/Conclusion |
Power Frequency Voltage |
39kV 5min Not Flashover and Not Breakdown |
Pass |
Partial Discharge |
Under 15kV, Discharge volume≤10pc |
Pass |
Impulse Voltage Test |
Under 95kV, ±10 times,No breakdown no flashover |
Not Flashover and Not Breakdown |
Constant Voltage load Cycle (in air) |
The conductor applied voltage 23kV,and heated to (95-100ºC). In which the temperature stability 2h,cooling 3h, a total of 3 cycles |
Not Flashover and assessed by the following test results |
Partial Discharge (the normal operation of the high temperature and conductor 5-10ºC) |
Under 15kV, Discharge volume≤10pc |
Pass |
Constant load Cycle Test |
The conductor applied voltage 23kV, and heated to (95-100ºC). In which the temperature stability 2h, cooling 3h, a total of 60 cycles |
Not Flashover and assessed by the following test results |
Partial Discharge (the normal operation of the high temperature and conductor 5-10ºC,and at ambient temperature) |
Under 15kV, Discharge volume≤10pc |
Pass |
Thermal Stability Test |
Under 23 KA, Short circuit 2 times, No visible damage |
Pass |
Dynamic Stability Test |
Under 81 KA, Short circuit 1 time, No visible damage |
Pass |
Impulse Voltage Test |
95kV, ±10 times |
Not Flashover and Not Breakdown |
AC Withstand Voltage |
23kV, 15min |
Not Flashover and Not Breakdown |
Tide Temperature Test |
11kV, 300h |
Not Flashover,Not Breakdown and No Overcurrent Release |
Salt Spray Test |
11kV, 1000h |
Not Flashover,Not Breakdown and No Overcurrent Release |
12/20KV 18/20KV-Cold Shrinkable Cable Accessories
Name |
Item No. |
Suit cables' sectional area (sqmm) |
Name |
Item No. |
Suit cables' sectional area (sqmm) |
18/20kV 3-cores Cold Shrinkable Indoor Termination Kits |
VLN-20/3.1 |
35~70 |
18/20kV Single Core Cold Shrinkable Indoor Termination Kits |
VLN-10/1.1 |
35~70 |
VLN-20/3.2 |
95~185 |
VLN-10/1.2 |
95~185 |
VLN-20/3.3 |
240~400 |
VLN-10/1.3 |
240~400 |
VLN-20/3.4 |
500~630 |
VLN-10/1.4 |
500~630 |
18/20kV 3-cores Cold Shrinkable Outdoor Termination Kits |
VLW-20/3.1 |
35~70 |
18/20kV Single Core Cold Shrinkable Outdoor Termination Kits |
VLW-10/1.1 |
35~70 |
VLW-20/3.2 |
95~185 |
VLW-10/1.2 |
95~185 |
VLW-20/3.3 |
240~400 |
VLW-10/1.3 |
240~400 |
VLW-20/3.4 |
500~630 |
VLW-10/1.4 |
500~630 |
18/20kV 3-cores Cold Shrinkable Joint |
VLJ-20/3.1 |
35~70 |
18/20kV Single Core Cold Shrinkable Joint |
VLJ-10/1.1 |
35~70 |
VLJ-20/3.2 |
95~185 |
VLJ-10/1.2 |
95~185 |
VLJ-20/3.3 |
240~400 |
VLJ-10/1.3 |
240~400 |
VLJ-20/3.4 |
500~630 |
VLJ-10/1.4 |
500~630 |
Test Project |
Standard Requirements |
Test Result/Conclusion |
Power Frequency Voltage |
54kV 5min Not Flashover and Not Breakdown |
Pass |
Partial Discharge |
Under 20kV, Discharge volume≤10pc |
Pass |
Impulse Voltage Test |
Under 125kV, ±10 times,No breakdown no flashover |
Not Flashover and Not Breakdown |
Constant Voltage load Cycle (in air) |
The conductor applied voltage 35kV,and heated to (95-100ºC). In which the temperature stability 2h,cooling 3h, a total of 3 cycles |
Not Flashover and assessed by the following test results |
Partial Discharge (the normal operation of the high temperature and conductor 5-10ºC) |
Under 20kV, Discharge volume≤10pc |
Pass |
Constant load Cycle Test |
The conductor applied voltage 35kV, and heated to (95-100ºC). In which the temperature stability 2h, cooling 3h, a total of 60 cycles |
Not Flashover and assessed by the following test results |
Partial Discharge (the normal operation of the high temperature and conductor 5-10ºC,and at ambient temperature) |
Under 20kV, Discharge volume≤10pc |
Pass |
Thermal Stability Test |
Under 23 KA, Short circuit 2 times, No visible damage |
Pass |
Dynamic Stability Test |
Under 81 KA, Short circuit 1 time, No visible damage |
Pass |
Impulse Voltage Test |
125kV, ±10 times |
Not Flashover and Not Breakdown |
AC Withstand Voltage |
30kV, 15min |
Not Flashover and Not Breakdown |
Tide Temperature Test |
15kV, 300h |
Not Flashover,Not Breakdown and No Overcurrent Release |
Salt Spray Test |
15kV, 1000h |
Not Flashover,Not Breakdown and No Overcurrent Release |
26/35KV-Cold Shrinkable Cable Accessories
Name |
Item No. |
Suit cables' sectional area (sqmm) |
Name |
Item No. |
Suit cables' sectional area (sqmm) |
26/35kV 3-cores Cold Shrinkable Indoor Termination Kits |
VLN-35/3.1 |
50~95 |
26/35kV Single Core Cold Shrinkable Indoor Termination Kits |
VLN-35/1.1 |
35~70 |
VLN-35/3.2 |
120~185 |
VLN-35/1.2 |
95~185 |
VLN-35/3.3 |
240~400 |
VLN-35/1.3 |
240~400 |
VLN-35/3.4 |
500~630 |
VLN-35/1.4 |
500~630 |
26/35kV 3-cores Cold Shrinkable Outdoor Termination Kits |
VLW-35/3.1 |
50~95 |
26/35kV Single Core Cold Shrinkable Outdoor Termination Kits |
VLW-35/1.1 |
35~70 |
VLW-35/3.2 |
120~185 |
VLW-35/1.2 |
95~185 |
VLW-35/3.3 |
240~400 |
VLW-35/1.3 |
240~400 |
VLW-35/3.4 |
500~630 |
VLW-35/1.4 |
500~630 |
26/35kV 3-cores Cold Shrinkable Joint |
VLJ-35/3.1 |
50~95 |
26/35kV Single Core Cold Shrinkable Joint |
VLJ-35/1.1 |
35~70 |
VLJ-35/3.2 |
120~185 |
VLJ-35/1.2 |
95~185 |
VLJ-35/3.3 |
240~400 |
VLJ-35/1.3 |
240~400 |
VLJ-35/3.4 |
500~630 |
VLJ-35/1.4 |
500~630 |
Test Project |
Standard Requirements |
Test Result/Conclusion |
Power Frequency Voltage |
105kV 1min Not Flashover and Not Breakdown |
Pass |
Partial Discharge |
Under 39kV, Discharge volume≤10pc |
Pass |
Constant Voltage load Cycle (in air) |
The conductor applied voltage 23kV,and heated to (95-100ºC). In which the temperature stability 2h,cooling 3h, a total of 3 cycles |
Not Flashover and assessed by the following test results |
Impulse Voltage Test |
Under 250kV, ±10 times,No breakdown no flashover |
Not Flashover and Not Breakdown |
DC Voltage |
156kV, 15min |
Not Flashover and Not Breakdown |
AC Withstand Voltage |
104kV, 4h |
Not Flashover and Not Breakdown |